Horiba Jobin Yvon - Fluorescence Spectroscopy

Steady-State Fluorescence


FluoroMax®-4

The World's Most Sensitive Analytical Spectrofluorometer
The new FluoroMax®-4 is a compact spectrofluorometer from Spex®, yet it offers the ultimate sensitivity in fluorescence investigations as well as features not found in most table-top fluorescence detection systems. The FluoroMax®-4 now has 33% higher sensitivity and 20% better signal-to-noise ratio!

  • Water Raman signal-to-noise ratio: 3000:1
  • Photon Counting for Ultimate Sensitivity
  • Fast Scanning capability - up to 80 nm/second
  • Powerful new FluorEssence™ software for Windows®
  • Front Surface Detection, Fluorescence Microscope and Polarisation and Anisotropy Accessories
  • Remote Measurement Capability using optical fibres
  • Time-correlated single-photon counting (TCSPC) accessory for lifetime determinations
  • Phosphorimeter accessory for long-lived luminescence determinations

The FluoroLog-3

The FluoroLog®-3 spectrofluorometer is the ultimate in modular research fluorescence system. With sensitivity and flexibility unequaled, it will perform analyses over the ultraviolet and visible regions of the fluorescence spectrum as well as far into the IR.

  • Can detect 50-femtomolar fluorescein
  • Unique, modular system adapts to new experiments or changing techonolgy so is never obsolete
  • Interchange wide range of computer-controlled accessories: spectrometers, detectors, sources, and more!
  • Totally computer-controlled
  • All-reflective optics so that the sample is in focus at all wavelengths


Aqualog is the only instrument to simultaneously measure both absorbance spectra and fluorescence Excitation-Emission Matrices. EEMs are acquired up to a 100 times faster than with other instruments. Dedicated software automates traceable Quinine Sulfate Unit calibration and correction of inner-filter effects and Rayleigh and Raman scattering lines, enabling rapid export to modeling algorithms like PARAFAC.

 

Fluorescence Lifetime - Frequency Domain


FluoroLog® Tau-3

Tau Fluorescence Lifetime Spectrofluorometer. The FluoroLog® Tau-3 Fluorescence Lifetime and Steady-State Spectrofluorometer is a complete, stand-alone spectrofluorometer with both lifetime and steady-state modes.

  • Highest sensitivity-even with a xenon source (cw laser optional)
  • Flexibility with sources-no expensive pulse lasers are needed
  • Flattest frequency response over the full frequency range
  • Fast selection of lifetime or steady-state operation
  • Upgrades for any FluoroLog-3 to lifetime capability

 

Fluorescence Lifetime - Time Domain


FluoroLog®-TCSPC

Time-Correlated Single-Photon Counting on the World's Most Sensitive Spectrofluorometer. The World's Most Sensitive Spectrofluorometer, with TCSPC ready to perform time-domain lifetime spectroscopy! You get the reliability and know-how of the Spex® FluoroLog® series, together with the solid-state economy and sensitivity of IBH lifetime analysis, all in one instrument. All functions are software controlled from a host computer, giving you access to data with just a few keystrokes. A high repetition rate light source rapidly builds up a histogram of the sample's fluorescence decay.

 



FluoroCube

Picoseconds to seconds: a compact fluorescence system optimised for use in the time-domain. The FluoroCube combines the latest miniaturized light source and detector technology with proven TCSPC electronics and automation to offer the most flexible and user friendly photon counting lifetime system available today. Choose from the most comprehensive range of pulsed light source and detector options, including:

  • Picosecond laser diodes from 370nm to NIR
  • Nanosecond LEDs from 260nm to NIR
  • The original nanosecond flashlamp; now in its 4th generation
  • Sub-microsecond xenon flashlamp and LEDs for phosphorescence
  • Ti-sapphire laser and multi-photon options
  • Highly integrated picosecond PMT modules
  • Microchannel plate PMTs

 

 

Microscopy & Mapping


FluoroMap

The Spex® FluoroMap features high sensitivity, confocal microscopy with spatial resolution down to 1 mm, wide spectral response from the UV to near-IR, and time resolution down to the picosecond range, all in one modular instrument. The FluoroMap is a flexible, automated system for mapping fluorescence lifetime and emission.


TCSPC Confocal Microscope

HORIBA Jobin Yvon introduces a filter-based confocal system (the DynaMicT) to measure fluorescence lifetime and intensity directly under the microscope in the deep UV and visible (240-850 nm). With TCSPC's unequalled sensitivity, this microscope-fluorescence system finds wide applications in biotechnology and nanotechnology. The DynaMicT is especially useful for intrinsic protein fluorescence measurements, such as distinguishing tryptophan and tyrosine, with the 295 nm LED

 

Remote Sensing


SkinSkan

The only in-vivo, fiber-optic spectrofluorometer. Designed specifically for skin-fluorescence and hair-fluorescence measurements. It is also ideal for many remote sensing steady-state fluorescence applications such as plants or sea life.

  • A quartz fibre bundle selectively delivers uv-nir radiation to the subject, then collects the resulting fluorescence. There's no need for sample preparation, cuvettes, or adaptation.
  • Unique spectrometer designs isolate the fluorescence signal from strong scattered backgrounds.
  • Fast wavelength scanning minimises the time of measurement and exposure to excitation light.
  • Compact and transportable to take the instrument to where the action is.

LifeSurf

Remote sensing fluorescence lifetime system for studying surfaces. Capable of performing fluorescence lifetime measurements on any surface. A key application concerns the in-vivo monitoring of skin for medical, healthcare, sun-screening and cosmetics research and others such as:

  • Skin Monitoring
  • Medical screening
  • NDE on materials
  • Paints
  • Catalysts
  • Ceramics
  • Semiconductors
  • Industrial QA

 

Process Monitoring


UrAssay

A turn-key uranium assay system with 0.1ppb sensitivity. Uses time-domain to achieve accurate measurements even on samples which would normally need extensive chemical pre-treatment.

  • Measures uranyl concentrations from 0.1ppb to 40.0ppb
  • Minimal chemical pre-treatment required
  • Rapid - performs a measurement in under a minute
  • Corrects for quenching due to contaminants
  • Rejects short-lived fluorescence from organic contaminants
  • HORIBA Jobin Yvon IBH can customise to meet specific measurement and reporting requirements

Other models or configurations may be available. Please contact us with your application reqirements.

News & Announcements

  • IMPORTANT UPDATE! The workshop has been moved to November 30 to December 1

    SIRIM, in cooperation with Horiba Scientific are holding a workshop, "Photoluminescence of Sol-Gel Derived Materials and Optical Fibers for Photonic Applications." Read More...

Get in touch with us!

ALV Technologies Sdn Bhd
Unit A-6(1), 6th Floor, Excella Business Park, Jalan Ampang Putra, Taman Ampang Hilir,
55100 Kuala Lumpur, Malaysia.

Tel :+603 - 4270 5386
Fax : +603 - 4270 4386
malaysia@analytical-online.com